Military Institute of Science and Technology
MIST Digital Archive

Calibration of Thermal Power in the 3 MW TRIGA MARK II Research Reactor and Validation under Forced Convection Cooling

dc.contributor.authorMd Shamim Hassan
dc.contributor.authorK.M. Rakib Al Hasan
dc.contributor.authorMd. Rezouanul Kabir Hridoy
dc.contributor.authorMohammed Sarim Salman karim
dc.contributor.authorMd. Ashiqur Rahman Alif
dc.contributor.authorMd. Altab Hossain
dc.contributor.authorAshraful Haque
dc.date.accessioned2026-08-23T02:52:20Z
dc.date.issued2026-06-30
dc.description.abstractNeutronic instruments are commonly used by reactor operators to monitor reactor power; however, thermal methods remain the standard for calibrating reactor power during routine operation. This paper presents the results of thermal power calibration for the 3 MW TRIGA MARK II research reactor, comparing two heat transfer approaches: the calorimetric method and the heat balance method. Calibration data were validated under forced convection cooling conditions. The calorimetric method was applied at a low power level of 100 kW, yielding a thermal power measurement of 98 kW, closely matching the reactor’s design specifications. The heat balance method was employed at higher power levels of 1 MW, 1.5 MW, and 2 MW, based on measurements of inlet and outlet coolant temperatures and water flow rate in the primary cooling loop. The thermal power values obtained were 831.5 kW, 1293.5 kW, and 1755.4 kW, respectively. Deviations were mainly attributed to limitations in analog instrumentation, fluctuations in mass flow rate, and measurement uncertainties. Comparison of the two methods indicated that the calorimetric method provided more accurate and reliable power calibrations, whereas the heat balance method exhibited greater discrepancies. Overall, the findings underscore the suitability of the calorimetric method for precise thermal power calibration of TRIGA MARK II reactors.
dc.identifier.otherhttps://doi.org/10.47981/j.mijst.14(01)2026.566(141-150)
dc.identifier.urihttp://hdl.handle.net/123456789/1109
dc.language.isoen_US
dc.publisherResearch and Development Wing, MIST
dc.titleCalibration of Thermal Power in the 3 MW TRIGA MARK II Research Reactor and Validation under Forced Convection Cooling
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
11-566_galley.pdf
Size:
698.85 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: