DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2

MIST Central Library Repository

Show simple item record

dc.contributor.author Noman, Mashruf Ahmad
dc.contributor.author Rafique, Maimuna Torsa
dc.contributor.author Toma, Prionkari Banik
dc.date.accessioned 2019-03-13T04:21:07Z
dc.date.available 2019-03-13T04:21:07Z
dc.date.issued 2017-01
dc.identifier.uri http://hdl.handle.net/123456789/430
dc.description At first we are thankful to the Almighty, for His blessings and for giving us the courage and enthusiasm accompanied by which we have completed the thesis successfully in due time. We specially thank and express our profound gratitude to our respected thesis supervisor, Prof Dr. Dipak Kanti Das for his constant & meticulous supervision, valuable suggestions and encouragement to carry out this thesis. With due respect, we are also grateful to our respected dean Brig Gen Md. Lutfor Rahman, EME as well as Lt Col Golam Saklayen, EME and Lt Cdr K M R Sadi, (E), BN. We express indebtedness to Shimanto Square authority, Bashundhara Group authority and Bangladesh Bank authority. Finally we would like to thank everybody who supported us in any respect for the completion of the thesis. It has been a marvelous experience to work with such an esteemed faculty to carry out this thesis under one of the most reputable engineering institution of Bangladesh. en_US
dc.description.abstract In perspective of power consumption in the sector of energy in Bangladesh the central air conditioning system is a desirable solution nowadays. The purpose of this thesis is to design a central air conditioning system for Military Institute of Science and Technology (MIST) tower building-2. The suggested design includes cooling load calculation, duct design and the specification of system components (chiller, air handling unit etc.). The cooling load is calculated for individual classrooms, laboratories and departmental offices. The selection of ducting system consists of duct diameter, friction loss, air flow velocity and air flow rate passing through the ducts. The central air conditioning system will maintain a constant air temperature desired for human comfort for a defined space. This system can be efficiently maintained rather than a split or individual one. We are hoping that, this design will be productive for MIST in case of cost effectiveness and power consumption. en_US
dc.language.iso en en_US
dc.publisher DEPARTMENT OF MECHANICAL ENGINEERING MILITARY INSTITUTE OF SCIENCE AND TECHNOLOGY MIRPUR CANTONMENT, DHAKA - 1216, BANGLADESH en_US
dc.title DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2 en_US
dc.type Thesis en_US